Industry workers such as those who work in field services, utilities, mining, oil and gas and those who work in areas where flammable substances are produced, transported, stored or used are often exposed to harsh and dangerous environments. These workers are exposed to extremely difficult conditions, meaning they need extremely rugged and safe devices that can survive through these environments whilst keeping workers safe.
Peak Technologies are a supplier of ATEX rated products, which our team can match to your industry and workers needs so you can find the most suitable intrinsically safe solutions.
Peak Technologies ATEX Solutions
Mobile Computing Devices
Communication Solutions
Lone Worker Protection
Intrinsically Safe Or Explosion Proof?
Explosion Proof
Intrinsic Safety
An “intrinsically safe” protection, instead, means that the electronics or wiring contained within the product is engineered in such a way that it cannot accumulate enough energy to ignite the gas or vapor.
Intrinsic safety approach, then, mainly deals with limiting energy in the circuits to a level below that required to ignite a specific hazardous atmospheric mixture, both in normal condition and in case of failure.
This is typically achieved through the use of intrinsically safe interfaces (or barriers), that are classified in two categories:
Zener barriers – they divert excess energy to earth through the Zener diodes
Galvanic isolators – they provide isolation between the circuits in the hazardous area and those in the safe area, using relays, optoisolators and above all transformers.
The Main Differences And Weigh Pros And Cons Of The Two Protection Methods:
Explosion Proof
- Functioning: Contains the explosion.
- Price: Normally more expensive.
- Power: Less limitation of power. Also high power devices can be used safely in the Hazardous Area.
- Maintenance: No live maintenance permitted, you cannot open the enclosure while powered.
- Wiring requirements: X.P. wiring requires conduit and seals to isolate the circuit from hazardous gases.
- Hazardous Zones: Only suitable for use . 1n Zone 1 and Zone 2, not in Zone 0.
Intrinsic Safety
- Functioning: Limits energy in the circuit.
- Price: Normally cheaper.
- Power: The entire power of the system is controlled and !imitated. This can be a problem if the product needs to operate 1n a power range higher than allowed.
- Maintenance: Live maintenance permitted, there's no need to shut down the system.
- Wiring requirements: I.S. wiring IS easier. Usually there's no need for the conduit and seals, but you will need an intrinsically safe barrier.
- Hazardous Zones: Suitable for use in Zone 0, Zone 1 and Zone 2.